Description / Boiler
Model

500

650

800

1000

1250

1600

2000

2500

3000

3500

4000

5000

6000

8000

10000

Lengths

A-Overall length

1930

2075

2195

2370

2633

3080

3370

3720

4040

4245

4450

4940

5300

6030

6370

 

B-Length of Boiler

1800

1945

2065

220

2463

2910

3200

3590

3910

4115

4270

4750

5020

5670

6200

 

C-Length of Skid

1900

2045

2165

2250

2515

2910

3200

3840

4160

4365

4470

4850

5120

5720

6000

 

D-Estimated Burner length

530

530

530

600

600

650

650

650

700

700

700

700

700

900

900

 

E-Dist.to swing Front Door

778

834

862

832

918

877

945

1018

1060

1050

1153

1185

1260

1378

1535

 

F-Dist.to swing Rear Door

542

542

542

622

645

790

875

860

959

975

1075

1157

1236

1324

1395

 

G-Dist. Front Tube Replacing

1570

1710

1830

1965

2200

2575

2870

3210

3530

3735

3840

4320

4590

5190

5700

 

H-Required Rear Dist.

1000

1000

1000

1100

1100

1200

1200

1300

1300

1400

1500

1500

1600

1800

2000

Width

I-Overall Boiler Width

1580

1580

1580

1680

1740

1910

2010

2120

2220

2290

2430

2530

2680

2830

3030

 

J-Boiler Shell Width

1275

1275

1275

1364

1425

1600

1700

1800

1900

1970

2100

2200

2350

2500

2700

 

K-Width of Skid

925

925

925

1000

1075

1250

1350

1450

1650

1620

1750

1850

200

2150

2320

 

L-Estimated Dist.skid to pump

400

400

420

420

420

430

440

440

450

450

450

470

470

500

500

Heights

M-Overall Height

1920

1920

1920

2010

2100

2500

2580

2700

2750

2750

2850

300

3100

3450

3800

 

N-Floor to Shell Height

1550

1550

1550

1650

1700

1050

2100

2250

2250

2250

2350

2450

2550

2750

3100

 

O-Floor to normal water level height

1136

1136

1136

1202

1227

1425

1508

1545

1677

1623

1770

1895

20012

2305

2300

 

P-Floor to smoke outlet

950

950

1050

1050

1150

1300

1400

1400

1530

1570

1650

1830

1875

2225

2500

 

Q-Floor to Burner

825

825

825

848

873

985

11043

1055

1122

1155

1220

1295

1387

1600

1630

Connection

R-Location Steam valve

1415

1545

1665

1900

1978

2260

2450

2565

2960

3165

3070

3450

3820

3920

4550

 

S-Location Safety valve

205

220

220

275

300

600

425

600

500

500

550

650

600

750

800

 

T-Location Water level Regulator

230

230

230

240

240

510

550

550

550

550

600

600

600

700

700

 

U-Location water level limiter

250

250

250

270

350

350

350

400

400

420

450

450

450

450

500

  V- Location feed water connection

800

900

1000

1400

1850

1850

1950

1900

2420

1900

2220

2350

2450

2900

3800

 

W-Height feed water connection

1088

1100

1088

1148

1388

1388

1476

1513

1627

1666

1736

1870

1987

2282

2275

 

X-Smoke outlet Diameter

220

220

280

280

350

350

400

450

450

450

500

550

600

700

750

Inspection

Y-Manhole Size

300/400

300/400

300/400

300/400

300/400

300/400

320/420

320/420

320/420

320/420

320/420

320/420

320/420

320/420

320/420

Holes

Z- Handhole Size

115/165

115/165

115/165

115/165

115/165

220/320

220/320

220/320

220/320

220/320

220/320

220/320

220/320

220/320

220/320

Size

AA- Size steam supply connection

11/4

11/4

11/2

2"

2"

25"

25"

3"

3"

3"

4"

4"

45"

5"

5"

Connection

BB-Size feed water connection

1"

1"

1"

1"

1"

11/4"

11/4"

11/4"

11/4"

11/4"

11/4"

11/2"

11/2"

2"

2"

 

CC- Size blowdown connection

1"

1"

1"

1"

1"

11/4"

11/4"

11/4"

11/4"

11/4"

11/4"

2"

2"

2"

2"


Back to Top